    A502 Liquid Hydrocarbon Flash Vaporization Sampling and Injection System
     
    Product Introduction
    The A502 Liquid Hydrocarbon Flash Vaporization Sampling and Injection System is a specialized sample pretreatment and gasification device for analyzing liquid hydrocarbons and other liquefied gases.
    The A502 is referenced in GB/T 3727-2003, Determination of Trace Water in Ethylene and Propylene for Industrial Use, and GB/T 6023-2008, Determination of Trace Water in Butadiene for Industrial Use — Coulometric Karl Fischer Method.
    The system converts a liquid hydrocarbon sample into a gas-phase sample with consistent composition, controlled temperature, controlled pressure, and adjustable flow rate before analysis. This provides a stable and representative gas sample for subsequent trace-component measurement.
    The A502 is suitable for use with coulometric trace moisture analyzers, dew point meters, trace oxygen analyzers, gas chromatographs, and other analytical instruments.


    Key Features
    •  Designed for liquid hydrocarbon flash vaporization and sample injection
    •  Converts liquid samples into controlled gas-phase samples before analysis
    •  Provides controlled and stable sample temperature
    •  Supports adjustable gas flow rate and zero-point adjustment
    •  Compatible with multiple analytical instruments
    •  Suitable for trace moisture analysis in ethylene, propylene, butadiene, and other industrial olefins
    •  Can be used with coulometric Karl Fischer trace moisture analyzers
    •  Compatible with dew point meters for moisture analysis
    •  Suitable for trace oxygen analysis when connected to a trace oxygen analyzer
    •  Supports CO and CO₂ analysis by gas chromatography
    •  Suitable for liquid hydrocarbon composition analysis by GC
    •  Can be used for trace sulfur and arsenic analysis
    •  Applicable to trace moisture analysis of refrigerants and SF₆
    •  Flexible sample volume setting from 0 to 9.998 L
    •  Supports unlimited cumulative injection when the free-volume mode is selected


    Working Principle
    The A502 uses flash vaporization technology to convert a liquid hydrocarbon sample into a controlled gas-phase sample.
    The liquid sample enters the vaporization system and is heated to the specified temperature. Under controlled pressure and flow conditions, the liquid rapidly vaporizes while maintaining the sample composition as consistently as possible.
    The resulting gas is then delivered to the downstream analytical instrument at a controlled flow rate.
    The system provides adjustable temperature control from 0 to 230°C, while the mass flow controller regulates the sample flow. By controlling the vaporization temperature, pressure, flow, and sample volume, the A502 helps provide stable sample conditions for trace-component analysis.


    Technical Parameters
    Parameter Specification
    Model A502
    Product Type Liquid Hydrocarbon Flash Vaporization Sampling and Injection System
    Main Function Liquid-to-gas sample pretreatment and injection
    Applicable Standards GB/T 3727-2003; GB/T 6023-2008
    Mass Flow Meter Range 50 mL, 100 mL, 1 L, 2 L, 10 L options
    Flow Control Accuracy 0.1 L/min, adjustable according to selected range
    Mass Flow Meter Zero Point Adjustable
    Temperature Control Range 0–230°C, freely adjustable
    Temperature Control Accuracy ±0.1°C
    Sample Volume Setting 0–9.998 L
    Fixed Volume Mode Available below 9.998 L
    Free Volume Mode 9.998 L setting enables unlimited cumulative injection
    Dimensions 520 × 360 × 260 mm
    Weight Approx. 5 kg


    Applications
    The A502 Liquid Hydrocarbon Flash Vaporization Sampler is designed for sample pretreatment in a wide range of liquid hydrocarbon and liquefied gas analyses.
    Trace Moisture Analysis
    Used with a coulometric trace moisture analyzer or dew point meter for trace water analysis in:
    •  Ethylene
    •  Propylene
    •  Butadiene
    •  Other industrial olefins
    •  Refrigerants
    •  SF₆
    Trace Oxygen Analysis
    The vaporized sample can be supplied to a trace oxygen analyzer for determining trace oxygen in industrial olefins and other liquefied hydrocarbon samples.
    CO and CO₂ Analysis
    When combined with a gas chromatograph, the A502 can provide controlled gas-phase samples for trace carbon monoxide and carbon dioxide analysis.
    Liquid Hydrocarbon Composition Analysis
    The system can be used as a sample pretreatment unit before gas chromatographic analysis of liquid hydrocarbon composition.
    Trace Sulfur and Arsenic Analysis
    The A502 can also support sample introduction and pretreatment for trace sulfur, arsenic, and other components in liquid hydrocarbon samples.


    Comparison: A502 vs. Conventional Liquid Hydrocarbon Sampling
    Feature A502 Flash Vaporization Sampler Conventional Manual Sampling
    Liquid-to-Gas Conversion Controlled flash vaporization More manual
    Temperature Control 0–230°C Often less precise
    Temperature Accuracy ±0.1°C Operator dependent
    Flow Control Adjustable mass flow control Manual or external control
    Zero Adjustment Supported Not always available
    Sample Volume Programmable Usually manual
    Gas Sample Stability High under controlled conditions More variable
    GC Compatibility Yes Yes, depending on system
    Trace Moisture Analysis Supported Possible but more handling required
    Continuous Injection Available in free-volume mode Usually limited
    The A502 Liquid Hydrocarbon Flash Vaporization Sampling and Injection System simplifies the conversion of liquid hydrocarbon samples into controlled gas-phase samples. Its precise temperature control, adjustable flow rate, and programmable sample volume make it suitable for reliable sample introduction into various analytical instruments.


    FAQ
    1. What is the A502 used for?
    The A502 is used to vaporize liquid hydrocarbons and other liquefied gases before analysis, providing a controlled gas-phase sample for downstream analytical instruments.
    2. Which standards reference the A502 application?
    The A502 application is referenced in GB/T 3727-2003 for trace water determination in industrial ethylene and propylene and GB/T 6023-2008 for trace water determination in industrial butadiene using the coulometric Karl Fischer method.
    3. Can the A502 be used for trace moisture analysis?
    Yes. It can be used with coulometric Karl Fischer trace moisture analyzers or dew point meters.
    4. Can the A502 be connected to a gas chromatograph?
    Yes. The vaporized gas sample can be supplied to a GC for liquid hydrocarbon composition analysis and trace CO/CO₂ analysis.
    5. What is the temperature control range?
    The temperature can be freely set from 0 to 230°C, with a control accuracy of ±0.1°C.
    6. What mass flow meter ranges are available?
    Optional ranges include 50 mL, 100 mL, 1 L, 2 L, and 10 L.
    7. Can the sample volume be freely adjusted?
    Yes. The sample volume can be set between 0 and 9.998 L. When 9.998 L is selected, the system enters a free-volume accumulation mode that allows unlimited cumulative injection.
    8. What types of samples can be analyzed?
    The A502 is suitable for liquid hydrocarbons, industrial olefins, liquefied gases, refrigerants, SF₆, and other samples requiring controlled liquid-to-gas conversion before analysis.


  • FAQ
    1. What is the A502 used for?
    The A502 is used to vaporize liquid hydrocarbons and other liquefied gases before analysis, providing a controlled gas-phase sample for downstream analytical instruments.
    2. Which standards reference the A502 application?
    The A502 application is referenced in GB/T 3727-2003 for trace water determination in industrial ethylene and propylene and GB/T 6023-2008 for trace water determination in industrial butadiene using the coulometric Karl Fischer method.
    3. Can the A502 be used for trace moisture analysis?
    Yes. It can be used with coulometric Karl Fischer trace moisture analyzers or dew point meters.
    4. Can the A502 be connected to a gas chromatograph?
    Yes. The vaporized gas sample can be supplied to a GC for liquid hydrocarbon composition analysis and trace CO/CO₂ analysis.
    5. What is the temperature control range?
    The temperature can be freely set from 0 to 230°C, with a control accuracy of ±0.1°C.
    6. What mass flow meter ranges are available?
    Optional ranges include 50 mL, 100 mL, 1 L, 2 L, and 10 L.
    7. Can the sample volume be freely adjusted?
    Yes. The sample volume can be set between 0 and 9.998 L. When 9.998 L is selected, the system enters a free-volume accumulation mode that allows unlimited cumulative injection.
    8. What types of samples can be analyzed?
    The A502 is suitable for liquid hydrocarbons, industrial olefins, liquefied gases, refrigerants, SF₆, and other samples requiring controlled liquid-to-gas conversion before analysis.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com