2050 type comprehensive ambient air sampler Introduction: This instrument utilizes the filter weighing method to capture total suspended particulate matter (TSP) and inhalable particulate matter (PM10) or fine particulate matter (PM2.5, optional) in ambient air; it employs the solution absorption method to collect various pollutant gas components (such as SO2, NOx, etc.) in ambient air and indoor air; it can also be used for sampling volatile organic compounds (VOCs) in ambient air. It can be used by departments such as environmental protection, health, labor, safety supervision, military, scientific research, and education for routine or emergency monitoring of particulate matter, gaseous substances, and aerosols. Implementation standard: GB/T 18883-2022 Indoor Air Quality Standards GB/T 39193-2020 Ambient Air - Determination of Mass Concentration of Particulate Matter - Gravimetric Method GB 50325-2020 Standard for Indoor Environmental Pollution Control of Civil Building Engineering HJ 93-2013 Technical Requirements and Test Methods for Ambient Air Particulate Matter (PM10 and PM2.5) Samplers HJ/T 374-2007 Technical Requirements and Test Methods for Total Suspended Particulate Matter Samplers HJ/T 375-2007 Technical Requirements and Testing Methods for Ambient Air Samplers HJ 618-2011 Determination of PM10 and PM2.5 in Ambient Air - Gravimetric Method HJ 644-2013 Determination of Volatile Organic Compounds in Ambient Air - Adsorption Tube Sampling - Thermal Desorption Gas Chromatography-Mass Spectrometry Method HJ 645-2013 Ambient Air - Determination of Volatile Halogenated Hydrocarbons - Activated Carbon Adsorption - Carbon Disulfide Desorption/Gas Chromatography Method HJ 683-2014 Ambient Air - Determination of Aldehydes and Ketones - High-Performance Liquid Chromatography Method HJ 1263-2022 Ambient Air - Determination of Total Suspended Particulate Matter - Gravimetric Method JJG 943-2011 Total Suspended Particulate Matter Sampler JJG 956-2013 Atmospheric sampler Features: 1. It serves multiple purposes, featuring simultaneous sampling capabilities for 5 gas circuits, with each circuit's sampling flow rate independently set and controlled by a separate constant flow system 2. It can serve as a four-channel ambient air sampler and a TSP/PM10/(PM2.5 optional) particulate matter sampler simultaneously 3. It can be applied to the sampling of VOCs in ambient air using solid-phase adsorption method 4. Integrated thermostat design, capable of housing up to 4 absorption bottles 5. Automatic control of sampling flow: Utilizing high-precision, corrosion-resistant electronic flowmeters 6. Precision core pump, corrosion-resistant, ultra-low noise, maintenance-free for continuous operation, adaptable to various working conditions, and equipped with overload protection function 7. Equipped with a built-in lithium battery, it features both AC and DC power supply capabilities 8. Equipped with a large-capacity internal memory, allowing for storage, viewing, exporting, and printing of sampled data 9. Measure parameters such as atmospheric pressure and ambient temperature in real-time. 10. Equipped with a fault self-checking function, it can detect the functions of the instrument and indicate faults, facilitating user maintenance and use Technical parameters: Particulate matter sampling flow rate: Maximum no-load flow rate of 150L/min, with customizable flow rate at the working point Atmospheric sampling flow rate: Standard configuration (0~1.0) L/min, C/D paths can be customized (10~200) mL/min Sampling time: Settable within 99 hours and 59 minutes Temperature before flowmeter: (-30~99)°C Pressure before flowmeter: (-45~0) kPa Thermostatic control: (15~30)℃ Atmospheric pressure: (50~130) kPa Load capacity: At a flow rate of 100L/min, it can overcome a resistance of 6kPa Instrument noise: <62dB(A) Dimensions: (Length × Width × Height) 380mm × 186mm × 254mm Host weight: about 5.0kg Working power supply: Built-in lithium battery (11.1V/15.6Ah) or external AC220V50Hz power supply Power consumption: <120W Technical specifications of sampling head TSP collection particle size: <100um PM10 cutting characteristics: Da50=(10±0.5)μmog=1.5±0.1 PM2.5 cutting characteristics: Da50=(2.5±0.2)μm og=1.2±0.1 Deviation in air inlet size: not exceeding ±2.0% Entry speed: 0.3m/s Effective filter diameter: Φ80mm Connector: M20×1.5
Introduction: This instrument utilizes the filter weighing method to capture total suspended particulate matter (TSP) and inhalable particulate matter (PM10) or fine particulate matter (PM2.5, optional) in ambient air; it employs the solution absorption method to collect various pollutant gas components (such as SO2, NOx, etc.) in ambient air and indoor air; it can also be used for sampling volatile organic compounds (VOCs) in ambient air. It can be used by departments such as environmental protection, health, labor, safety supervision, military, scientific research, and education for routine or emergency monitoring of particulate matter, gaseous substances, and aerosols.