Position: Home > > Environmental monitoring and analysis > Gaseous pollutants > Air detector > 2029 type ultraviolet gas analyzer

2029 type ultraviolet gas analyzer

Product ID:HQWRkq059

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model Number2029
    Brand NameQDLAOYING
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    2029 type ultraviolet gas analyzer
    Introduction:
    The instrument is based on the characteristic absorption spectra of odor gases containing sulfur and nitrogen, such as ammonia, trimethylamine, hydrogen sulfide, sulfur dioxide, nitric oxide, nitrogen dioxide, ozone, methyl mercaptan, dimethyl sulfide, dimethyl disulfide, carbon disulfide, styrene, and aldehydes and ketones such as formaldehyde, acetaldehyde, benzaldehyde, acetone, and isopentanone; aromatic hydrocarbons such as benzene, toluene, xylene, and ethylbenzene; and olefinic organic gases such as 1,3-butadiene and isoprene, in the ultraviolet region. Utilizing a high-resolution spectrometer and a long-path gas absorption cell design, the high-resolution low detection limit multi-component gas monitor can continuously monitor the real-time concentrations of the aforementioned gases emitted from fugitive emission sources, work environments, and indoor spaces in industrial and mining enterprises, and calculate odor intensity.
    Implementation standard
    GB14554-93 Emission Standards for Odor Pollutants
    GB/T37186-2018 Determination of sulfur dioxide and nitrogen oxides in gas analysis by ultraviolet differential absorption spectroscopy
    DB37/T 3786-2019 Determination of Gaseous Pollutants Such as Hydrogen Sulfide in Ambient Air - Open Path Ultraviolet Absorption Spectrometry
    EU Performance Test Standard for Open-Path Ambient Air Quality Monitoring Systems Utilizing Differential Optical Absorption Spectroscopy (DOAS) and FTIR Infrared Spectroscopy
    EPA Method To 16: Method for Determining Toxic Organic Compounds in Ambient Air
    Features:
    1. It can detect organic gases such as ammonia, trimethylamine, hydrogen sulfide, sulfur dioxide, nitric oxide, nitrogen dioxide, ozone, methyl mercaptan, dimethyl sulfide, dimethyl disulfide, carbon disulfide, styrene, and other sulfur- and nitrogen-containing odor gases; aldehydes and ketones such as formaldehyde, acetaldehyde, benzaldehyde, acetone, and isopentanone; aromatic hydrocarbons such as benzene, toluene, xylene, and ethylbenzene; and olefins such as 1,3-butadiene and isoprene
    2. According to needs, it can be extended to measure the gas concentrations of aromatic hydrocarbons such as aniline, phenol, chlorobenzene, naphthalene, and anthracene, sulfur-containing organic compounds such as dimethyl sulfoxide, nitrogen-containing organic compounds such as ethylamine, formamide, and acetamide, olefinic organic compounds such as ethylene, butene, isobutene, and styrene, aldehyde organic compounds such as formaldehyde, acetaldehyde, and benzaldehyde, and heterocyclic organic compounds such as pyrrole, pyridine, and thiophene in industrial parks
    3. Utilizing UV differential absorption spectroscopy, the detection items are numerous, and standard molecular spectra can be added according to requirements to increase monitoring items
    4. Human-machine dialogue operation interface, illustrated with both text and images, provides rich online operation prompts, making the operation simple
    The structural design is reasonable, suitable for portable emergency and vehicle-mounted mobile monitoring
    6. Equipped with a built-in lithium battery, it can operate for an extended period of time without external mains power
    7. Equipped with a large-capacity internal memory, the sampling data can be stored, viewed, exported, and printed
    Scope of application:
    1. Emergency monitoring and safety inspection for environmental emergencies
    2. On-board mobile monitoring in industrial parks and urban road motor vehicle pollution monitoring
    3. Detection of odor gas emissions from urban sewage treatment plants and landfills
    4. Investigation of odor from fugitive emission sources by environmental monitoring departments
    5. On-site analysis of specific pollutants by the Center for Disease Control and Prevention (CDC) and the Emergency Center
    Self-inspection of fugitive emissions from factories, mines, and enterprises
    7. Environmental impact assessment conducted by environmental assessment departments at all levels
    8 Indoor industrial hygiene monitoring

     
     
  • Introduction:
    The instrument is based on the characteristic absorption spectra of odor gases containing sulfur and nitrogen, such as ammonia, trimethylamine, hydrogen sulfide, sulfur dioxide, nitric oxide, nitrogen dioxide, ozone, methyl mercaptan, dimethyl sulfide, dimethyl disulfide, carbon disulfide, styrene, and aldehydes and ketones such as formaldehyde, acetaldehyde, benzaldehyde, acetone, and isopentanone; aromatic hydrocarbons such as benzene, toluene, xylene, and ethylbenzene; and olefinic organic gases such as 1,3-butadiene and isoprene, in the ultraviolet region. Utilizing a high-resolution spectrometer and a long-path gas absorption cell design, the high-resolution low detection limit multi-component gas monitor can continuously monitor the real-time concentrations of the aforementioned gases emitted from fugitive emission sources, work environments, and indoor spaces in industrial and mining enterprises, and calculate odor intensity.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter