Position: Home > > Analytical instruments > Chromatogram > Chromatography / UV / evaporative emission detector > UM5800 evaporative light scattering detector for HPLC system combination

UM5800 evaporative light scattering detector for HPLC system combination

Product ID:FSjian005

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberUM5800
    Brand NameYIMA
    Payment TermsT/T, paypal
    Brief introduction:
    At present, the instrument has been widely applied in the carbohydrate, lipid, fatty acids, amino acids, drugs and polymer detection, especially traditional Chinese medicine and Chinese patent medicine without determination of ultraviolet absorption of active ingredients. Can be used with any HPLC system online; Can detect volatile below any samples of the mobile phase; Low-temperature evaporation and meet the requirements for high temperature and evaporation conditions, and at the same time to provide you with more choices;
    Features:
    1. The optimized circuit design, reduce the instrument noise level;
    2. Has a wider testing dynamic range, the same map can display a larger span of quality to the samples;
    3. Effectively reduce the peak broadening, and improve the resolution;
    4. The atomization mechanism tear open outfit simple and easy to clean;
    5. Product volume greatly compressed, save space; Matters and make our products more professional fashion. Compact internal structure more reasonable, better reduce electromagnetic interference, more comprehensive and effective to improve the comprehensive detection performance of the product;
    6. At first large size color touch-screen control ELSD, significantly improve the intelligent level of instruments and ease of use;
    7. The new temperature, flow, pressure alarm function, and improve equipment stability, reliability and security.
    Technical indicators
    Power: 220 v, 50 hz
    Size: 460 * 330 * 330 (mm)
    Environmental conditions: temperature 15 to 40 relative humidity < 90%
    Evaporation temperature range: room temperature to 130
    Temperature control increment: 1
    The temperature control accuracy: + / - 1
    Gas: nitrogen or air
    Gas input pressure range: 2 bar - 5 bar
    Gas pressure precision: 0.01 bar
    Gas flow range: 1 L/min - 4 L/min
    Accuracy of gas flow rate: 1%, or 0.02 L/min or less
    Liquid flow range: 10 mL/min L/min-3
    Light source: 650 nm semiconductor laser
    Detection element: photo multiplier tube
    Baseline noise: mV <0.03
    Baseline drift: mV/h <0.3
    Minimum detection limit: ng <1
    Typical quantitative range: 0.1 μg ~30 μg (glucose)
     

  • Brief introduction:
    At present, the instrument has been widely applied in the carbohydrate, lipid, fatty acids, amino acids, drugs and polymer detection, especially traditional Chinese medicine and Chinese patent medicine without determination of ultraviolet absorption of active ingredients. Can be used with any HPLC system online; Can detect volatile below any samples of the mobile phase; Low-temperature evaporation and meet the requirements for high temperature and evaporation conditions, and at the same time to provide you with more choices; 
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com