QL - 800 trace blood lead tester

Product ID:SHLCxq002

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Brand NameYM
    Payment TermsT/T, paypal
    Model NumberQL - 800
    Features:
    1. Static mercury electrode technology, improve the sensitivity and stability of the instrument, make the results more accurate
    2. Biological colloid microelectrode technique, reduces the reagent dosage, realized the closed measurement, avoid the pollution to the sample measurement
    3. The real dual channel technology: the right channel to detect lead, copper, cadmium in the left channel detecting zinc iron calcium magnesium, manganese, etc., dual channel can be run at the same time
    4. The analysis process in six seconds (when measuring lead cadmium copper to 70 seconds), 8 kinds of element each time measurement only about two minutes
    5. Protein precipitator technology: avoid the protein in the samples such as organic matter influence on measurement results
    6. The quadratic differential potentiometric stripping waveform technology, make traditional into two and three o peak
    7. Allergic electrode: blood lead measurement using imported allergic glassy carbon electrode, ensure the accuracy of measurement results
    8: small sample use quantity measuring cadmium lead zinc copper or iron calcium magnesium manganese elements such as HP only 20 (including l
    9. With functions of background deducted automatically, effectively reduce the detection limit of more than 10 times
    10. Can automatically search the peak, to avoid the manual for the peak effects on measurement results
    11. The automatic calibration, testing process can be timely and fast calibration instrument
    12. Can do import and domestic functions related to quality control
    13. Modular design, hardware and software can be upgraded
    Technical indicators:
    Potentiometric stripping method:
    Detection limit: 0.01 or less
    Ability to resist to restore material: > 5000:1
    Repeatability error % : RSD < 3
    The precision of the calibration curve: % RSD < 8
    Linear relationship: R 0.9990 or higher
    Polarographic method:
    Detection limit 5 x 10 or less - 8 mol/L
    Ability to resist to restore material > 5000:1
    Repeatability error % RSD < 1
    The precision of the calibration curve % RSD < 2
    The linear relationship between R 0.9990 or higher
     
  • 1. Static mercury electrode technology, improve the sensitivity and stability of the instrument, make the results more accurate
    2. Biological colloid microelectrode technique, reduces the reagent dosage, realized the closed measurement, avoid the pollution to the sample measurement
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com