Position: Home > > Physical property test > Thermal analysis instrument > Differential scanning calorimeter > HQC-1 HQC-2 HQC-3 HQC-4 automatic microcomputer differential heat meter

HQC-1 HQC-2 HQC-3 HQC-4 automatic microcomputer differential heat meter

Product ID:WLcs024

Price: Please inquire PDF Format
Supply Ability:90 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberHQC-1 HQC-2 HQC-3 HQC-4
    Brand NameBEIJINGHENGJIUSHIYAN
    Payment TermsT/T, paypal
    HQC-1 HQC-2 HQC-3 HQC-4 automatic microcomputer differential heat meter
    Introduction
    An instrument that measures the temperature difference between a substance and a reference as a function of temperature under programmed temperature control.
    HQC-1 HQC-2 HQC-3 HQC-4 fully automatic microcomputer differential heat meter is widely used in the research of basic science fields such as chemistry, physics, geology, biology and chemical industry, metallurgy, geology, electrical engineering, ceramics, textiles , Food, medicine, agriculture, forestry, fire protection and other industries, manufacturing enterprises, scientific research units and colleges.
    HQC-1 HQC-2 HQC-3 HQC-4 fully automatic microcomputer differential heat meter is used to study the phase change, decomposition, combination, dehydration, adsorption, analysis, dissolution, solidification, sublimation, evaporation and other phenomena of substances and to identify substances Analysis, component analysis, thermal parameter determination and kinetic parameter determination, etc.
     
    Feature
    The furnace body can be lifted and controlled automatically, and the positioning is accurate, which improves the repeatability of the measurement.
    The atmosphere control system uses a mass flow controller, and two channels of stable and stable gas can be changed during the experiment, with high accuracy, good repeatability, and fast response (an atmosphere control system that can resist various corrosive gases can be customized).
    The entire measurement process is completed automatically, automatic drawing, and DTA routine data processing can be completed using software functions; special data processing (DTA peak area, enthalpy calculation, kinetic parameter calculation, data comparison, multiple algorithms to calculate activation energy, glass transition temperature, Comparative method to measure specific heat, etc.).
    During the sample collection process, the system can take screenshots at any time and automatically change the range according to the output signal size.
    Users can use their own standard samples such as indium, tin, and lead to calibrate the accuracy of the instrument's temperature and energy.
    Large-screen liquid crystal display, real-time display of the instrument status and data, two sets of temperature measuring thermocouples, one set of real-time display furnace temperature (regardless of whether the furnace is working or not), and another set of thermocouples display the sample temperature during work.
    The user gives the calculation formula or calculation method, and our factory can provide the corresponding software to develop the product.
    Independently developed constant temperature controller; constant temperature gas chromatography, mass spectrometry connector; constant temperature zone; can fully guarantee the secondary detection of tar and various reaction gases.
     
    Technical Parameters
    DSC data
    DSC measurement range: ± 1mW to ± 100mW
    DSC accuracy: ± 0.1 μW
    Temperature data
    temperature range:
    HQC-1: Room temperature to 1150 ° C
    HQC-2: room temperature to 1250 ℃
    HQC-3: Room temperature to 1450 ° C
    HQC-4: Room temperature to 1550 ° C
    Temperature accuracy: ± 0.1 ℃
    Heating rate: 0.1 ℃ / min ~ 100 ℃ / min
    Vacuum degree (the instrument itself has vacuum sealing measures)
    Optional vacuum unit can reach 2.66 × 10-2 Pa
    Atmospheric control system adopts mass flow controller
    Constant temperature controller, constant temperature gas chromatography, mass spectrometer connector; constant temperature zone (optional)
    Constant temperature range: room temperature to 400 ° C
    Differential Thermal Data (DTA)
    Measurement range: ± 10μv ± 2000μv
    DTA resolution: 0.01μv
    crucible
    Standard configuration: ceramic crucible 0.06ml or 0.12ml
    Select configuration: aluminum crucible, graphite crucible, quartz crucible, platinum crucible

  • HQC-1 HQC-2 HQC-3 HQC-4 fully automatic microcomputer differential heat meter is widely used in the research of basic science fields such as chemistry, physics, geology, biology and chemical industry, metallurgy, geology, electrical engineering, ceramics, textiles , Food, medicine, agriculture, forestry, fire protection and other industries, manufacturing enterprises, scientific research units and colleges. HQC-1 HQC-2 HQC-3 HQC-4 fully automatic microcomputer differential heat meter is used to study the phase change, decomposition, combination, dehydration, adsorption, analysis, dissolution, solidification, sublimation, evaporation and other phenomena of substances and to identify substances Analysis, component analysis, thermal parameter determination and kinetic parameter determination.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com