Position: Home > > Life science instrument and equipment > Molecular biology instrument > Nucleic acid purification / extraction > Auto-Pure10B automatic nucleic acid extractor for Medical Biological Research

Auto-Pure10B automatic nucleic acid extractor for Medical Biological Research

Product ID:SHFZhsch032

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberAuto-Pure10B
    Brand NameHANGZHOUAOSHENG
    Payment TermsT/T, paypal
    Auto-Pure10B automatic nucleic acid extractor
     
    Introduction:
    Auto-Pure10B/10BS/Auto-Pure16A automatic nucleic acid extraction instrument is a miniaturized magnetic bead method nucleic acid extraction and purification instrument developed on the basis of Auto-Pure20B and Auto-Pure32A. The 10 series can extract up to 10 samples at the same time, the maximum sample processing volume is 5ml, and there are multiple models to choose from. Auto-Pure10BS integrates the metal bath heating function, and the extracted template can be subjected to subsequent processing such as isothermal amplification reaction, which is convenient Extract the detection results on site. Auto-Pure16A can process up to 16 samples at the same time, with a maximum sample processing volume of 1ml. With different types of magnetic bead nucleic acid reagents, it can quickly extract nucleic acids from animal and plant tissues, blood, body fluids, criminal specimens and other samples.
    Features:
    1. 4.3 inch color touch screen operation, easy to use
    2. Customize the temperature and program according to the requirements to meet the requirements of different reagents
    3. Short operating time, 15-40min/time
    4. High nucleic acid yield, low magnetic bead loss, and good repeatability of results
    5. Ultraviolet disinfection function to reduce the contamination of samples between different batches
    6. Open system, suitable for various magnetic bead extraction reagents
    7. APP software will be configured to monitor the system in real time through mobile devices
    8. It is easier to configure PC software, APP software, edit, set, and manage programs
    9. Screw design, high operation accuracy; large guide rail design, more stable and reliable structure;
    10. With QR code recognition function, it can be directly recognized by using special reagents without programming and calling programs
    11. Open instrument parameter settings, which can be set by yourself: mixing speed, magnetic attraction, release, cooling fan and other functions
    12. The instrument has a smaller footprint, is more portable, and is more suitable for on-site extraction
    Technical Parameters:
    Model: Auto-Pure10B
    Sample throughput: 1~10
    Processing volume: 50~5000μl
    Consumables used: 5ml kit + magnetic rod cover
    Purification sensitivity: The positive detection rate of 100 copies of samples>95%
    Difference between purification holes: CV<5%
    Cracking temperature: room temperature~120
    Elution temperature: room temperature~120
    Magnetic bead recovery rate: >95%
    Concussive mixing: Editable mixing methods for different needs
    Operation interface: 4.3-inch touch screen, 3 shortcut keys, external mouse
    Internal program: preset 6 groups of programs, 100 groups of programs can be stored
    Software management: PC software, APP software configuration, program editing and management are more convenient
    Expansion interface: standard USB, Ethernet port, wireless wifi
    Lighting system: Yes
    Sterilization: UV disinfection
    Exhaust method: fan
    Data storage: can be stored, built-in SD card
    Maximum input power: 300W
    Volume (W×D×H): 340mm×350mm×410mm
    Weight: 18KG
  • Introduction:
    Auto-Pure10B/10BS/Auto-Pure16A automatic nucleic acid extraction instrument is a miniaturized magnetic bead method nucleic acid extraction and purification instrument developed on the basis of Auto-Pure20B and Auto-Pure32A. The 10 series can extract up to 10 samples at the same time, the maximum sample processing volume is 5ml, and there are multiple models to choose from. Auto-Pure10BS integrates the metal bath heating function, and the extracted template can be subjected to subsequent processing such as isothermal amplification reaction, which is convenient Extract the detection results on site. Auto-Pure16A can process up to 16 samples at the same time, with a maximum sample processing volume of 1ml. With different types of magnetic bead nucleic acid reagents, it can quickly extract nucleic acids from animal and plant tissues, blood, body fluids, criminal specimens and other samples.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com