1476/A/B multi-standard RF/microwave signal source for Electronic product measurement

Product ID:CLQTwxdjl011

Price: Please inquire PDF Format
Supply Ability:60 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model Number1476/A/B
    Brand NameZHONGDIANKEYI
    Payment TermsT/T, paypal
    1476/A/B multi-standard RF/microwave signal source
     
    Introduction:
    The 1476A/1476B multi-standard RF/microwave signal source is a multi-function electronic measuring instrument, which is mainly used for the detection, maintenance and training of modern electronic equipment. It has a variety of modulation systems that can be used not only as ordinary signal sources but also for communication. Simulation of various complex signals such as radar and navigation, and can be edited to produce specific signal patterns according to actual needs, so as to be suitable for more occasions. For the convenience and flexibility of the operation, special shortcuts for special functions have also been specially designed.
    The multi-standard RF/microwave signal source has self-checking and calibration functions; it has a memory recall function to make complex operation of a specific function button simple; and has combined modulation and power output control functions, including CW, amplitude modulation, frequency modulation, phase modulation, and pulse Modulation, frequency agile output function, can simulate a variety of radar, navigation and other conventional and special system signals, pulse modulation, inter-pulse agile, heavy-frequency jitter, heavy-frequency jitter and other special system radar signal analog output capabilities; GPIB, USB, LAN, RS232 remote control interface for flexible configuration settings, function optimization and product upgrades to better meet user needs.
    Features:
    1. 1Hz frequency resolution
    2. Micro-second fast frequency hopping capability
    3. High power dynamic range and high power accuracy
    4. Digital baseband signal generation and vector modulation
    5. Frequency modulation / amplitude modulation / phase modulation / pulse modulation and combined modulation
    6. Multiple radar signal simulation capabilities
    7. Certain complex signal programming capabilities
    8. Built-in digital synthesis modulation source
    9. Multiple scanning methods: digital stepping, frequency hopping, phase continuous
    application:
    The 1476 series of signal sources are widely used in signal simulation and parameter testing in many fields such as radar, communication, navigation, and electronic countermeasures. It has various radar signal simulation functions such as ordinary pulse radar, ordinary continuous wave radar, frequency agile radar, linear frequency modulation radar, heavy frequency staggered radar and heavy frequency jitter radar, which can meet the performance test and maintenance guarantee of radar receiving equipment; Frequency hopping, digital modulation and spread spectrum functions, and various digital modulation signal generation functions such as BPSK, QPSK, and MSK can meet the performance test and maintenance of communication receiving equipment.
     
    If you want to know more, please ask for more instruments related technical documents.
     
  • Introduction:
    The 1476A/1476B multi-standard RF/microwave signal source is a multi-function electronic measuring instrument, which is mainly used for the detection, maintenance and training of modern electronic equipment. It has a variety of modulation systems that can be used not only as ordinary signal sources but also for communication. Simulation of various complex signals such as radar and navigation, and can be edited to produce specific signal patterns according to actual needs, so as to be suitable for more occasions. For the convenience and flexibility of the operation, special shortcuts for special functions have also been specially designed.
    The multi-standard RF/microwave signal source has self-checking and calibration functions; it has a memory recall function to make complex operation of a specific function button simple; and has combined modulation and power output control functions, including CW, amplitude modulation, frequency modulation, phase modulation, and pulse Modulation, frequency agile output function, can simulate a variety of radar, navigation and other conventional and special system signals, pulse modulation, inter-pulse agile, heavy-frequency jitter, heavy-frequency jitter and other special system radar signal analog output capabilities; GPIB, USB, LAN, RS232 remote control interface for flexible configuration settings, function optimization and product upgrades to better meet user needs.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis